{"id":10473,"date":"2024-10-14T10:08:03","date_gmt":"2024-10-14T10:08:03","guid":{"rendered":"https:\/\/www.pvcconduitmanufacturer.com\/?p=10473"},"modified":"2026-03-31T09:40:26","modified_gmt":"2026-03-31T09:40:26","slug":"choosing-the-right-flexible-electrical-conduit-for-outdoor-use-a-comprehensive-guide","status":"publish","type":"post","link":"https:\/\/www.pvcconduitmanufacturer.com\/id\/choosing-the-right-flexible-electrical-conduit-for-outdoor-use-a-comprehensive-guide\/","title":{"rendered":"Memilih Pipa Konduit Listrik Fleksibel yang Tepat untuk Penggunaan di Luar Ruangan: Panduan Komprehensif"},"content":{"rendered":"<div id=\"ez-toc-container\" class=\"ez-toc-v2_0_85 ez-toc-light-blue ez-toc-container-direction\">\n<div class=\"ez-toc-title-container\">\n<p class=\"ez-toc-title\" style=\"cursor:inherit\">Daftar isi<\/p>\n<span class=\"ez-toc-title-toggle\"><a href=\"#\" class=\"ez-toc-pull-right ez-toc-btn ez-toc-btn-xs ez-toc-btn-default ez-toc-toggle\" aria-label=\"Toggle Table of Content\"><span class=\"ez-toc-js-icon-con\"><span class=\"\"><span class=\"eztoc-hide\" style=\"display:none;\">Alihkan<\/span><span class=\"ez-toc-icon-toggle-span\"><svg style=\"fill: #999;color:#999\" xmlns=\"http:\/\/www.w3.org\/2000\/svg\" class=\"list-377408\" width=\"20px\" height=\"20px\" viewbox=\"0 0 24 24\" fill=\"none\"><path d=\"M6 6H4v2h2V6zm14 0H8v2h12V6zM4 11h2v2H4v-2zm16 0H8v2h12v-2zM4 16h2v2H4v-2zm16 0H8v2h12v-2z\" fill=\"currentColor\"><\/path><\/svg><svg style=\"fill: #999;color:#999\" class=\"arrow-unsorted-368013\" xmlns=\"http:\/\/www.w3.org\/2000\/svg\" width=\"10px\" height=\"10px\" viewbox=\"0 0 24 24\" version=\"1.2\" baseprofile=\"tiny\"><path d=\"M18.2 9.3l-6.2-6.3-6.2 6.3c-.2.2-.3.4-.3.7s.1.5.3.7c.2.2.4.3.7.3h11c.3 0 .5-.1.7-.3.2-.2.3-.5.3-.7s-.1-.5-.3-.7zM5.8 14.7l6.2 6.3 6.2-6.3c.2-.2.3-.5.3-.7s-.1-.5-.3-.7c-.2-.2-.4-.3-.7-.3h-11c-.3 0-.5.1-.7.3-.2.2-.3.5-.3.7s.1.5.3.7z\"\/><\/svg><\/span><\/span><\/span><\/a><\/span><\/div>\n<nav><ul class='ez-toc-list ez-toc-list-level-1' ><li class='ez-toc-page-1 ez-toc-heading-level-2'><a class=\"ez-toc-link ez-toc-heading-1\" href=\"https:\/\/www.pvcconduitmanufacturer.com\/id\/choosing-the-right-flexible-electrical-conduit-for-outdoor-use-a-comprehensive-guide\/#1_Introduction\" >1. Pendahuluan<\/a><\/li><li class='ez-toc-page-1 ez-toc-heading-level-2'><a class=\"ez-toc-link ez-toc-heading-2\" href=\"https:\/\/www.pvcconduitmanufacturer.com\/id\/choosing-the-right-flexible-electrical-conduit-for-outdoor-use-a-comprehensive-guide\/#2_What_is_Electrical_Flexible_Conduit\" >2. What is Electrical Flexible Conduit?<\/a><\/li><li class='ez-toc-page-1 ez-toc-heading-level-2'><a class=\"ez-toc-link ez-toc-heading-3\" href=\"https:\/\/www.pvcconduitmanufacturer.com\/id\/choosing-the-right-flexible-electrical-conduit-for-outdoor-use-a-comprehensive-guide\/#3_Whats_the_Difference_Between_Flexible_and_Rigid_Conduits\" >3. What\u2019s the Difference Between Flexible and Rigid Conduits?<\/a><\/li><li class='ez-toc-page-1 ez-toc-heading-level-2'><a class=\"ez-toc-link ez-toc-heading-4\" href=\"https:\/\/www.pvcconduitmanufacturer.com\/id\/choosing-the-right-flexible-electrical-conduit-for-outdoor-use-a-comprehensive-guide\/#4_Importance_of_Choosing_the_Right_Flexible_Conduit_for_Outside\" >4. Importance of Choosing the Right Flexible Conduit for Outside<\/a><\/li><li class='ez-toc-page-1 ez-toc-heading-level-2'><a class=\"ez-toc-link ez-toc-heading-5\" href=\"https:\/\/www.pvcconduitmanufacturer.com\/id\/choosing-the-right-flexible-electrical-conduit-for-outdoor-use-a-comprehensive-guide\/#5_What_Are_Different_Types_of_Electrical_Flexible_Conduit\" >5. What Are Different Types of Electrical Flexible Conduit?<\/a><\/li><li class='ez-toc-page-1 ez-toc-heading-level-2'><a class=\"ez-toc-link ez-toc-heading-6\" href=\"https:\/\/www.pvcconduitmanufacturer.com\/id\/choosing-the-right-flexible-electrical-conduit-for-outdoor-use-a-comprehensive-guide\/#6_What_is_Liquidtight_Flexible_Metal_Conduit\" >6. What is Liquidtight Flexible Metal Conduit?<\/a><\/li><li class='ez-toc-page-1 ez-toc-heading-level-2'><a class=\"ez-toc-link ez-toc-heading-7\" href=\"https:\/\/www.pvcconduitmanufacturer.com\/id\/choosing-the-right-flexible-electrical-conduit-for-outdoor-use-a-comprehensive-guide\/#7_What_is_Liquidtight_Flexible_Nonmetallic_Conduit\" >7. What is Liquidtight Flexible Nonmetallic Conduit?<\/a><\/li><li class='ez-toc-page-1 ez-toc-heading-level-2'><a class=\"ez-toc-link ez-toc-heading-8\" href=\"https:\/\/www.pvcconduitmanufacturer.com\/id\/choosing-the-right-flexible-electrical-conduit-for-outdoor-use-a-comprehensive-guide\/#8_What_is_Flexible_Metal_Conduit\" >8. What is Flexible Metal Conduit?<\/a><\/li><li class='ez-toc-page-1 ez-toc-heading-level-2'><a class=\"ez-toc-link ez-toc-heading-9\" href=\"https:\/\/www.pvcconduitmanufacturer.com\/id\/choosing-the-right-flexible-electrical-conduit-for-outdoor-use-a-comprehensive-guide\/#9_What_is_Electrical_Nonmetallic_Tubing\" >9. What is Electrical Nonmetallic Tubing?<\/a><\/li><li class='ez-toc-page-1 ez-toc-heading-level-2'><a class=\"ez-toc-link ez-toc-heading-10\" href=\"https:\/\/www.pvcconduitmanufacturer.com\/id\/choosing-the-right-flexible-electrical-conduit-for-outdoor-use-a-comprehensive-guide\/#10_What_is_High_Density_Polyethylene_Conduit\" >10. What is High Density Polyethylene Conduit?<\/a><\/li><li class='ez-toc-page-1 ez-toc-heading-level-2'><a class=\"ez-toc-link ez-toc-heading-11\" href=\"https:\/\/www.pvcconduitmanufacturer.com\/id\/choosing-the-right-flexible-electrical-conduit-for-outdoor-use-a-comprehensive-guide\/#11_Key_Environmental_Requirements_for_Outdoor_Flexible_Conduit\" >11. Key Environmental Requirements for Outdoor Flexible Conduit<\/a><\/li><li class='ez-toc-page-1 ez-toc-heading-level-2'><a class=\"ez-toc-link ez-toc-heading-12\" href=\"https:\/\/www.pvcconduitmanufacturer.com\/id\/choosing-the-right-flexible-electrical-conduit-for-outdoor-use-a-comprehensive-guide\/#12_Comparing_Different_Flexible_Conduit_Types\" >12. Comparing Different Flexible Conduit Types<\/a><\/li><li class='ez-toc-page-1 ez-toc-heading-level-2'><a class=\"ez-toc-link ez-toc-heading-13\" href=\"https:\/\/www.pvcconduitmanufacturer.com\/id\/choosing-the-right-flexible-electrical-conduit-for-outdoor-use-a-comprehensive-guide\/#13_Flexible_Electrical_Conduit_Codes_Standards_And_Certifications\" >13. Flexible Electrical Conduit Codes, Standards And Certifications<\/a><\/li><li class='ez-toc-page-1 ez-toc-heading-level-2'><a class=\"ez-toc-link ez-toc-heading-14\" href=\"https:\/\/www.pvcconduitmanufacturer.com\/id\/choosing-the-right-flexible-electrical-conduit-for-outdoor-use-a-comprehensive-guide\/#FAQs\" >Pertanyaan yang Sering Diajukan (FAQ)<\/a><\/li><\/ul><\/nav><\/div>\n<h2><span class=\"ez-toc-section\" id=\"1_Introduction\"><\/span>1. Pendahuluan<span class=\"ez-toc-section-end\"><\/span><\/h2>\n<p>Can flexible conduit be used outdoors? The answer is yes!<\/p>\n<p>\ud83c\udf1eBut to make sure your outdoor wiring stays safe and lasts long, you need to choose the right type of flexible electrical conduit that suits the outdoor environment.<\/p>\n<p>\ud83d\udd0dFor example, a contractor once installed a flexible conduit for a garden lighting system without considering outdoor conditions.<\/p>\n<p><span style=\"font-size: 16px; font-style: normal; font-weight: 400;\">\ud83c\udf27\ufe0f<\/span>After a rainy season, the metal conduit started to rust, causing damage and requiring costly replacement. Choosing the right rust-resistant outdoor flexible conduit from the start could have saved time and money.<\/p>\n<p><span style=\"font-size: 16px; font-style: normal; font-weight: 400;\">\ud83d\udcda <\/span>In this guide, we\u2019ll explore the different kinds of flexible conduits made for outdoor use, their materials, and how to pick the best one for your needs.<\/p>\n<p>\ud83d\udc77\u200d\u2642\ufe0fWhether you\u2019re a electrician, engineer, or contractor, this post meybe helpful.<\/p>\n<p><img fetchpriority=\"high\" decoding=\"async\" class=\"alignnone wp-image-13137\" src=\"https:\/\/www.pvcconduitmanufacturer.com\/wp-content\/uploads\/2023\/08\/What-is-Flexible-PVC-Conduit-ENT.jpg\" alt=\"Apa itu Pipa PVC Fleksibel (ENT)?\" width=\"800\" height=\"534\" title=\"\" srcset=\"https:\/\/www.pvcconduitmanufacturer.com\/wp-content\/uploads\/2023\/08\/What-is-Flexible-PVC-Conduit-ENT.jpg 1000w, https:\/\/www.pvcconduitmanufacturer.com\/wp-content\/uploads\/2023\/08\/What-is-Flexible-PVC-Conduit-ENT-300x200.jpg 300w, https:\/\/www.pvcconduitmanufacturer.com\/wp-content\/uploads\/2023\/08\/What-is-Flexible-PVC-Conduit-ENT-768x512.jpg 768w, https:\/\/www.pvcconduitmanufacturer.com\/wp-content\/uploads\/2023\/08\/What-is-Flexible-PVC-Conduit-ENT-18x12.jpg 18w\" sizes=\"(max-width: 800px) 100vw, 800px\" \/><\/p>\n<h2><span class=\"ez-toc-section\" id=\"2_What_is_Electrical_Flexible_Conduit\"><\/span>2. What is Electrical Flexible Conduit?<span class=\"ez-toc-section-end\"><\/span><\/h2>\n<p>Flexible conduits, as the name suggests, are bendable tubes made from materials like plastic or metal. They\u2019re designed to protect and guide electrical wires.<\/p>\n<p>Some types have a smooth outer surface, while others have a ridged or corrugated design.<\/p>\n<p>They can easily adapt to different layouts and environments, making them especially useful in tight spaces or areas where wires need to bend or move. This flexibility makes them a popular choice in many electrical installations.<\/p>\n<p>These conduits act like a flexible shield, protecting wires from moisture, dust, heat, and physical damage.<\/p>\n<h3 style=\"font-style: normal;\"><img decoding=\"async\" class=\"alignnone wp-image-10493\" src=\"https:\/\/www.pvcconduitmanufacturer.com\/wp-content\/uploads\/2024\/10\/Choosing-the-Right-Flexible-Electrical-Conduit-for-Outdoor-Use-Rigid-and-Flexible-Conduit.jpg\" alt=\"Choosing the Right Flexible Electrical Conduit for Outdoor Use Rigid and Flexible Conduit\" width=\"800\" height=\"534\" title=\"\" srcset=\"https:\/\/www.pvcconduitmanufacturer.com\/wp-content\/uploads\/2024\/10\/Choosing-the-Right-Flexible-Electrical-Conduit-for-Outdoor-Use-Rigid-and-Flexible-Conduit.jpg 1000w, https:\/\/www.pvcconduitmanufacturer.com\/wp-content\/uploads\/2024\/10\/Choosing-the-Right-Flexible-Electrical-Conduit-for-Outdoor-Use-Rigid-and-Flexible-Conduit-300x200.jpg 300w, https:\/\/www.pvcconduitmanufacturer.com\/wp-content\/uploads\/2024\/10\/Choosing-the-Right-Flexible-Electrical-Conduit-for-Outdoor-Use-Rigid-and-Flexible-Conduit-768x513.jpg 768w, https:\/\/www.pvcconduitmanufacturer.com\/wp-content\/uploads\/2024\/10\/Choosing-the-Right-Flexible-Electrical-Conduit-for-Outdoor-Use-Rigid-and-Flexible-Conduit-18x12.jpg 18w\" sizes=\"(max-width: 800px) 100vw, 800px\" \/><\/h3>\n<p>&nbsp;<\/p>\n<h2><span class=\"ez-toc-section\" id=\"3_Whats_the_Difference_Between_Flexible_and_Rigid_Conduits\"><\/span>3. What\u2019s the Difference Between Flexible and Rigid Conduits?<span class=\"ez-toc-section-end\"><\/span><\/h2>\n<p>Flexible wire conduit can be bent by hand without special tools, but rigid conduits are straight and require tools and fittings to cut and change direction.<\/p>\n<p>Rigid conduits also differ from flexible conduits in shape and surface texture. They typically have smooth inner and outer surfaces.<\/p>\n<p>These differences also determine the distinct installation methods, applications, and impact resistance between flexible and rigid conduits.<\/p>\n<p>Rigid conduits provide excellent protection but lack the adaptability needed for intricate routing.<\/p>\n<p>In contrast, flexible conduits allow for seamless transitions and adjustments without the need for additional fittings.<\/p>\n<h2><span class=\"ez-toc-section\" id=\"4_Importance_of_Choosing_the_Right_Flexible_Conduit_for_Outside\"><\/span>4. Importance of Choosing the Right Flexible Conduit for Outside<span class=\"ez-toc-section-end\"><\/span><\/h2>\n<p>As we mentioned earlier, using the correct flexible conduit for outdoor applications is vital; it can save you time and money by preventing damage and costly repairs.<\/p>\n<p>Outdoor environments expose conduits to tough challenges like UV radiation, moisture, and physical wear.<\/p>\n<p>So outdoor use flexible conduit is made from upgraded materials like UV-resistant plastic or corrosion-resistant metal.<\/p>\n<p>These materials offer better protection against sunlight, rain, and harsh weather conditions.<\/p>\n<p>Choosing the right conduit improves safety and extends the wiring system\u2019s lifespan. This reduces the risk of electrical failures and potential hazards.<\/p>\n<h2><span class=\"ez-toc-section\" id=\"5_What_Are_Different_Types_of_Electrical_Flexible_Conduit\"><\/span>5. What Are Different Types of Electrical Flexible Conduit?<span class=\"ez-toc-section-end\"><\/span><\/h2>\n<p>There are several ways to classify electrical flexible conduits.<\/p>\n<p>One common way to classify them is by whether they have an outer jacket and what materials they\u2019re made of.<\/p>\n<p>\ud83d\udcca\ud83e\uddf5To make it easier to understand, we\u2019ve grouped them just like in the diagram \u2014 into two main types: Jacketed and Unjacketed.<\/p>\n<p>\ud83d\udd0dIn the\u00a0 following sections, we\u2019ll stick to this classification <span style=\"font-size: 16px;\">and explain each category in detail to help you gain a clear and complete understanding of the flexible conduit options available.<\/span><\/p>\n<p><img decoding=\"async\" class=\"alignnone wp-image-10494\" src=\"https:\/\/www.pvcconduitmanufacturer.com\/wp-content\/uploads\/2024\/10\/Choosing-the-Right-Flexible-Electrical-Conduit-for-Outdoor-Use-Flexible-Conduit-Classification.png\" alt=\"Choosing the Right Flexible Electrical Conduit for Outdoor Use Flexible Conduit Classification\" width=\"800\" height=\"450\" title=\"\" srcset=\"https:\/\/www.pvcconduitmanufacturer.com\/wp-content\/uploads\/2024\/10\/Choosing-the-Right-Flexible-Electrical-Conduit-for-Outdoor-Use-Flexible-Conduit-Classification.png 1267w, https:\/\/www.pvcconduitmanufacturer.com\/wp-content\/uploads\/2024\/10\/Choosing-the-Right-Flexible-Electrical-Conduit-for-Outdoor-Use-Flexible-Conduit-Classification-300x169.png 300w, https:\/\/www.pvcconduitmanufacturer.com\/wp-content\/uploads\/2024\/10\/Choosing-the-Right-Flexible-Electrical-Conduit-for-Outdoor-Use-Flexible-Conduit-Classification-1024x576.png 1024w, https:\/\/www.pvcconduitmanufacturer.com\/wp-content\/uploads\/2024\/10\/Choosing-the-Right-Flexible-Electrical-Conduit-for-Outdoor-Use-Flexible-Conduit-Classification-768x432.png 768w, https:\/\/www.pvcconduitmanufacturer.com\/wp-content\/uploads\/2024\/10\/Choosing-the-Right-Flexible-Electrical-Conduit-for-Outdoor-Use-Flexible-Conduit-Classification-18x10.png 18w\" sizes=\"(max-width: 800px) 100vw, 800px\" \/><\/p>\n<p>Based on the picture above, Jacketed flexible conduits can be further classified by their material composition.<\/p>\n<p>\u2699\ufe0f One type has a metal core with a nonmetallic outer jacket, known as LFMC (Liquidtight Flexible Metal Conduit).<\/p>\n<p><span style=\"font-size: 16px;\">This type offers both flexibility and strong protection against water, oil, and outdoor conditions.<\/span><\/p>\n<p>\ud83d\udd27The other type is LFNC (Liquidtight Flexible Nonmetallic Conduit), which is made entirely of nonmetallic materials. It\u2019s lightweight, corrosion-resistant, and ideal for damp or harsh environments.<\/p>\n<p>\ud83d\udd39\ud83d\udd39\ud83d\udd39\ud83d\udd39\ud83d\udd39<\/p>\n<p>On the other hand, Unjacketed flexible conduits fall into two categories: FMC and FNC.<\/p>\n<p>\ud83d\udee0\ufe0f FMC (Flexible Metal Conduit) is usually made from galvanized steel or aluminum.\u00a0\u00a0It\u2019s strong and durable, making it a good choice for tough indoor or industrial environments.<\/p>\n<p>\ud83d\udd29 FNC (Flexible Nonmetallic Conduit) is made from materials like PVC or HDPE. It\u2019s lightweight, corrosion-resistant, and easier to handle, often used in lighter-duty applications.<\/p>\n<p>\ud83c\udfaf Next section, let\u2019s take a closer look at Flexible Electrical Conduits with Jackets in detailed.<\/p>\n<h2><span class=\"ez-toc-section\" id=\"6_What_is_Liquidtight_Flexible_Metal_Conduit\"><\/span><span style=\"font-size: 1.1em; font-weight: bold;\">6. What is Liquidtight Flexible Metal Conduit?<\/span><span class=\"ez-toc-section-end\"><\/span><\/h2>\n<p><span style=\"font-size: 16px;\">According to NEC article 350, liquidtight flexible metal conduit (LFMC) is a raceway of circular cross section having an outer liquidtight, nonmetallic, sunlight-resistant jacket over an inner flexible metal core.<\/span><\/p>\n<p><strong>Features<\/strong>:<\/p>\n<ul>\n<li><span style=\"font-size: 16px;\">Galvanized steel core<\/span><\/li>\n<li><span style=\"font-size: 16px;\">Waterproof plastic outer jacket<\/span><\/li>\n<\/ul>\n<p><strong>Key Benefits:<\/strong><\/p>\n<ul>\n<li>Excellent waterproofing for wet environments<\/li>\n<li>Strong corrosion resistance from both metal and jacket<\/li>\n<li>High mechanical protection and impact resistance<\/li>\n<\/ul>\n<p><strong>Best for<\/strong>: <span style=\"font-size: 16px;\">Heavy-duty outdoor applications like garden wiring, poolside equipment, and exposed installations requiring strong protection.<\/span><\/p>\n<p><span style=\"font-size: 16px;\"><img loading=\"lazy\" decoding=\"async\" class=\"alignnone wp-image-12938\" src=\"https:\/\/www.pvcconduitmanufacturer.com\/wp-content\/uploads\/2023\/06\/liquid-tight-flexible-metal-conduit-LFMC.jpg\" alt=\"liquid tight flexible metal conduit (LFMC)\" width=\"800\" height=\"521\" title=\"\" srcset=\"https:\/\/www.pvcconduitmanufacturer.com\/wp-content\/uploads\/2023\/06\/liquid-tight-flexible-metal-conduit-LFMC.jpg 1500w, https:\/\/www.pvcconduitmanufacturer.com\/wp-content\/uploads\/2023\/06\/liquid-tight-flexible-metal-conduit-LFMC-300x195.jpg 300w, https:\/\/www.pvcconduitmanufacturer.com\/wp-content\/uploads\/2023\/06\/liquid-tight-flexible-metal-conduit-LFMC-1024x666.jpg 1024w, https:\/\/www.pvcconduitmanufacturer.com\/wp-content\/uploads\/2023\/06\/liquid-tight-flexible-metal-conduit-LFMC-768x500.jpg 768w, https:\/\/www.pvcconduitmanufacturer.com\/wp-content\/uploads\/2023\/06\/liquid-tight-flexible-metal-conduit-LFMC-18x12.jpg 18w\" sizes=\"(max-width: 800px) 100vw, 800px\" \/><\/span><\/p>\n<p>According to UL listings, LFMC conduits are made from materials like aluminum, brass, copper, or stainless steel.<\/p>\n<p>\u26a1\ufe0f The bonding strip must be made and sized to pass electrical resistance tests before high-current testing.<\/p>\n<p><span style=\"font-size: 16px; font-style: normal; font-weight: 400;\">\ud83d\udd04 <\/span>It should not reduce flexibility or make the conduit harder to bend.<\/p>\n<p>\ud83e\uddf5 A metal braiding can be added between the metal core and outer jacket.<\/p>\n<p>The braiding wire must be at least 0.005 inches (0.13 mm) thick.<\/p>\n<p>If the core is aluminum, the braiding must also be aluminum or tinned metal.<\/p>\n<p><span style=\"font-size: 16px;\">Sizes of Liquidtight Flexible Metal Conduit<\/span><span style=\"font-size: 16px;\"> meet the specified internal and external diameter measurements, as outlined in Table 5.1.\u00a0<\/span><\/p>\n<p><img loading=\"lazy\" decoding=\"async\" class=\"alignnone wp-image-10480\" src=\"https:\/\/www.pvcconduitmanufacturer.com\/wp-content\/uploads\/2024\/10\/Choosing-the-Right-Flexible-Electrical-Conduit-for-Outdoor-Use-LFMC-Sizes.png\" alt=\"Choosing the Right Flexible Electrical Conduit for Outdoor Use LFMC Sizes\" width=\"800\" height=\"419\" title=\"\" srcset=\"https:\/\/www.pvcconduitmanufacturer.com\/wp-content\/uploads\/2024\/10\/Choosing-the-Right-Flexible-Electrical-Conduit-for-Outdoor-Use-LFMC-Sizes.png 931w, https:\/\/www.pvcconduitmanufacturer.com\/wp-content\/uploads\/2024\/10\/Choosing-the-Right-Flexible-Electrical-Conduit-for-Outdoor-Use-LFMC-Sizes-300x157.png 300w, https:\/\/www.pvcconduitmanufacturer.com\/wp-content\/uploads\/2024\/10\/Choosing-the-Right-Flexible-Electrical-Conduit-for-Outdoor-Use-LFMC-Sizes-768x403.png 768w, https:\/\/www.pvcconduitmanufacturer.com\/wp-content\/uploads\/2024\/10\/Choosing-the-Right-Flexible-Electrical-Conduit-for-Outdoor-Use-LFMC-Sizes-18x9.png 18w\" sizes=\"(max-width: 800px) 100vw, 800px\" \/><\/p>\n<p>Sizes are for reference only. Please check with your supplier for exact specifications. Same as the following conduit sizes.<\/p>\n<h2><span class=\"ez-toc-section\" id=\"7_What_is_Liquidtight_Flexible_Nonmetallic_Conduit\"><\/span><span style=\"font-size: 1.1em; font-weight: bold;\">7. What is Liquidtight Flexible Nonmetallic Conduit?<\/span><span class=\"ez-toc-section-end\"><\/span><\/h2>\n<p><span style=\"font-size: 16px;\">LFNC is usually a round tube that can have a smooth or ribbed surface depending on the type. It is made from non-metallic plastic and has a protective outer jacket to resist corrosion and damage. Sometimes people call it FNMC.<\/span><\/p>\n<p><strong>Features:<\/strong><\/p>\n<ul>\n<li>Made of flexible non-metallic PVC or similar materials<\/li>\n<li>UV-resistant and waterproof<\/li>\n<\/ul>\n<p><strong>Key Benefits:<\/strong><\/p>\n<ul>\n<li>Lightweight and easy to install<\/li>\n<li>Cost-effective and naturally rust-proof<\/li>\n<li>Excellent in humid or coastal areas<\/li>\n<\/ul>\n<p><strong>Best for:<\/strong> <span style=\"font-size: 16px;\">Residential outdoor lighting, patio wiring, or areas where flexibility and moisture resistance are needed without heavy-duty protection.<\/span><\/p>\n<p><img loading=\"lazy\" decoding=\"async\" class=\"alignnone wp-image-12939\" src=\"https:\/\/www.pvcconduitmanufacturer.com\/wp-content\/uploads\/2023\/06\/liquid-tight-flexible-non-metallic-conduit-LFNC.jpeg\" alt=\"liquid tight flexible non metallic conduit (LFNC)\" width=\"800\" height=\"600\" title=\"\" srcset=\"https:\/\/www.pvcconduitmanufacturer.com\/wp-content\/uploads\/2023\/06\/liquid-tight-flexible-non-metallic-conduit-LFNC.jpeg 1890w, https:\/\/www.pvcconduitmanufacturer.com\/wp-content\/uploads\/2023\/06\/liquid-tight-flexible-non-metallic-conduit-LFNC-300x225.jpeg 300w, https:\/\/www.pvcconduitmanufacturer.com\/wp-content\/uploads\/2023\/06\/liquid-tight-flexible-non-metallic-conduit-LFNC-1024x768.jpeg 1024w, https:\/\/www.pvcconduitmanufacturer.com\/wp-content\/uploads\/2023\/06\/liquid-tight-flexible-non-metallic-conduit-LFNC-768x576.jpeg 768w, https:\/\/www.pvcconduitmanufacturer.com\/wp-content\/uploads\/2023\/06\/liquid-tight-flexible-non-metallic-conduit-LFNC-1536x1152.jpeg 1536w, https:\/\/www.pvcconduitmanufacturer.com\/wp-content\/uploads\/2023\/06\/liquid-tight-flexible-non-metallic-conduit-LFNC-16x12.jpeg 16w, https:\/\/www.pvcconduitmanufacturer.com\/wp-content\/uploads\/2023\/06\/liquid-tight-flexible-non-metallic-conduit-LFNC-640x480.jpeg 640w\" sizes=\"(max-width: 800px) 100vw, 800px\" \/><\/p>\n<p><span style=\"font-size: 16px;\">According to UL listed, LFNC is intended for use in wet, dry, or oily locations at a maximum of 60\u00b0C(140\u00b0F),unless otherwise marked.<\/span><\/p>\n<p>\ud83d\udd0dThere are three main types of LFNC based on their construction and surface design.<\/p>\n<p>\ud83d\udd35Let\u2019s take a closer look at each type.<\/p>\n<p>And for reference, we provide an overview of the key size requirements and testing methods for each LFNC type.<\/p>\n<p><span style=\"font-size: 16px; font-style: normal;\">\ud83d\udd34<\/span><strong>Type LFNC-A<\/strong>: Features a smooth, seamless inner core and cover bonded together, with one or more reinforcement layers between the core and the cover.<\/p>\n<p>\ud83d\udccf Must meet exact inside and outside diameter standards (see <strong>Table 1)<\/strong>.<\/p>\n<p>\u2705 Tested with go\/no-go gauges.<\/p>\n<p>\ud83d\udcd0 Jacket thickness is measured from 5 spots; smallest value is minimum allowed.<\/p>\n<p><img loading=\"lazy\" decoding=\"async\" class=\"alignnone wp-image-10482\" src=\"https:\/\/www.pvcconduitmanufacturer.com\/wp-content\/uploads\/2024\/10\/Choosing-the-Right-Flexible-Electrical-Conduit-for-Outdoor-Use-LFNC-Sizes.png\" alt=\"Choosing the Right Flexible Electrical Conduit for Outdoor Use LFNC Sizes\" width=\"800\" height=\"639\" title=\"\" srcset=\"https:\/\/www.pvcconduitmanufacturer.com\/wp-content\/uploads\/2024\/10\/Choosing-the-Right-Flexible-Electrical-Conduit-for-Outdoor-Use-LFNC-Sizes.png 813w, https:\/\/www.pvcconduitmanufacturer.com\/wp-content\/uploads\/2024\/10\/Choosing-the-Right-Flexible-Electrical-Conduit-for-Outdoor-Use-LFNC-Sizes-300x239.png 300w, https:\/\/www.pvcconduitmanufacturer.com\/wp-content\/uploads\/2024\/10\/Choosing-the-Right-Flexible-Electrical-Conduit-for-Outdoor-Use-LFNC-Sizes-768x613.png 768w, https:\/\/www.pvcconduitmanufacturer.com\/wp-content\/uploads\/2024\/10\/Choosing-the-Right-Flexible-Electrical-Conduit-for-Outdoor-Use-LFNC-Sizes-15x12.png 15w\" sizes=\"(max-width: 800px) 100vw, 800px\" \/><\/p>\n<p><span style=\"font-size: 16px; font-style: normal;\">\ud83d\udfe2 <\/span><strong>Type LFNC-B<\/strong>: Has a smooth inner surface with integral reinforcement within the raceway wall.<\/p>\n<p>\ud83d\udccf Has specific diameter requirements (<strong>Table 3<\/strong>), tested like LFNC-A.<\/p>\n<p>\ud83d\udcaa Reinforced jacket thickness measured at 3+ points between folds (<strong>Table 4<\/strong>).<\/p>\n<p><img loading=\"lazy\" decoding=\"async\" class=\"alignnone wp-image-10484\" src=\"https:\/\/www.pvcconduitmanufacturer.com\/wp-content\/uploads\/2024\/10\/Choosing-the-Right-Flexible-Electrical-Conduit-for-Outdoor-Use-LFNCB-Sizes.png\" alt=\"Choosing the Right Flexible Electrical Conduit for Outdoor Use LFNCB Sizes\" width=\"800\" height=\"712\" title=\"\" srcset=\"https:\/\/www.pvcconduitmanufacturer.com\/wp-content\/uploads\/2024\/10\/Choosing-the-Right-Flexible-Electrical-Conduit-for-Outdoor-Use-LFNCB-Sizes.png 819w, https:\/\/www.pvcconduitmanufacturer.com\/wp-content\/uploads\/2024\/10\/Choosing-the-Right-Flexible-Electrical-Conduit-for-Outdoor-Use-LFNCB-Sizes-300x267.png 300w, https:\/\/www.pvcconduitmanufacturer.com\/wp-content\/uploads\/2024\/10\/Choosing-the-Right-Flexible-Electrical-Conduit-for-Outdoor-Use-LFNCB-Sizes-768x684.png 768w, https:\/\/www.pvcconduitmanufacturer.com\/wp-content\/uploads\/2024\/10\/Choosing-the-Right-Flexible-Electrical-Conduit-for-Outdoor-Use-LFNCB-Sizes-13x12.png 13w\" sizes=\"(max-width: 800px) 100vw, 800px\" \/><\/p>\n<p><span style=\"font-size: 16px; font-style: normal;\">\ud83d\udfe0 <\/span><strong>Type LFNC-C<\/strong>: Characterized by a corrugated internal and external surface without integral reinforcement in the raceway wall.<\/p>\n<p>\ud83d\udccf Only minimum inside diameter is required (<strong>Table 5<\/strong>).<br data-start=\"687\" data-end=\"690\" data-immersive-translate-walked=\"b3f27ee0-4858-4717-bafb-043f19c54d89\" \/>\u274c No thickness standard for the jacket.<\/p>\n<p><img loading=\"lazy\" decoding=\"async\" class=\"alignnone wp-image-10485\" src=\"https:\/\/www.pvcconduitmanufacturer.com\/wp-content\/uploads\/2024\/10\/Choosing-the-Right-Flexible-Electrical-Conduit-for-Outdoor-Use-LFNCC-Sizes.png\" alt=\"Choosing the Right Flexible Electrical Conduit for Outdoor Use LFNCC Sizes\" width=\"800\" height=\"618\" title=\"\" srcset=\"https:\/\/www.pvcconduitmanufacturer.com\/wp-content\/uploads\/2024\/10\/Choosing-the-Right-Flexible-Electrical-Conduit-for-Outdoor-Use-LFNCC-Sizes.png 987w, https:\/\/www.pvcconduitmanufacturer.com\/wp-content\/uploads\/2024\/10\/Choosing-the-Right-Flexible-Electrical-Conduit-for-Outdoor-Use-LFNCC-Sizes-300x232.png 300w, https:\/\/www.pvcconduitmanufacturer.com\/wp-content\/uploads\/2024\/10\/Choosing-the-Right-Flexible-Electrical-Conduit-for-Outdoor-Use-LFNCC-Sizes-768x594.png 768w, https:\/\/www.pvcconduitmanufacturer.com\/wp-content\/uploads\/2024\/10\/Choosing-the-Right-Flexible-Electrical-Conduit-for-Outdoor-Use-LFNCC-Sizes-16x12.png 16w\" sizes=\"(max-width: 800px) 100vw, 800px\" \/><\/p>\n<p>&nbsp;<\/p>\n<h2><span class=\"ez-toc-section\" id=\"8_What_is_Flexible_Metal_Conduit\"><\/span><span style=\"font-size: 1.1em; font-weight: bold;\">8. What is Flexible Metal Conduit?<\/span><span class=\"ez-toc-section-end\"><\/span><\/h2>\n<p><span style=\"font-size: 16px;\">Flexible Metal Conduit (FMC)is a raceway of circular cross section made of helically wound, formed, interlocked metal strip.<\/span><\/p>\n<p><strong>Features:<\/strong><\/p>\n<ul>\n<li>Interlocked metal strip construction (steel or aluminum)<\/li>\n<li>No plastic sheath<\/li>\n<\/ul>\n<p><strong>Key Benefits:<\/strong><\/p>\n<ul>\n<li>Superior mechanical protection<\/li>\n<li>Excellent heat resistance<\/li>\n<\/ul>\n<p><strong>Best for<\/strong>: <span style=\"font-size: 16px;\">Outdoor environments that demand strong physical protection, but are not heavily exposed to water or humidity.<\/span><\/p>\n<p><img loading=\"lazy\" decoding=\"async\" class=\"alignnone wp-image-10490\" src=\"https:\/\/www.pvcconduitmanufacturer.com\/wp-content\/uploads\/2024\/10\/Choosing-the-Right-Flexible-Electrical-Conduit-for-Outdoor-Use-FMC.jpg\" alt=\"Choosing the Right Flexible Electrical Conduit for Outdoor Use FMC\" width=\"800\" height=\"533\" title=\"\" srcset=\"https:\/\/www.pvcconduitmanufacturer.com\/wp-content\/uploads\/2024\/10\/Choosing-the-Right-Flexible-Electrical-Conduit-for-Outdoor-Use-FMC.jpg 1024w, https:\/\/www.pvcconduitmanufacturer.com\/wp-content\/uploads\/2024\/10\/Choosing-the-Right-Flexible-Electrical-Conduit-for-Outdoor-Use-FMC-300x200.jpg 300w, https:\/\/www.pvcconduitmanufacturer.com\/wp-content\/uploads\/2024\/10\/Choosing-the-Right-Flexible-Electrical-Conduit-for-Outdoor-Use-FMC-768x512.jpg 768w, https:\/\/www.pvcconduitmanufacturer.com\/wp-content\/uploads\/2024\/10\/Choosing-the-Right-Flexible-Electrical-Conduit-for-Outdoor-Use-FMC-18x12.jpg 18w\" sizes=\"(max-width: 800px) 100vw, 800px\" \/><\/p>\n<p>Flexible Metal Conduit (FMC) can be made from different metals.<\/p>\n<p>\ud83d\udfe3 For flexible steel conduit, the strip material must be made of carbon steel with a minimum tensile strength of 34,000 lbf\/in\u00b2 (234.5 MPa).<\/p>\n<p>\ud83e\uddfd The strip should have a consistent width and thickness throughout for reliable quality. Also, before applying a protective zinc coating, all surfaces must be clean and free of rust or scale.<\/p>\n<p><span style=\"font-size: 16px; font-style: normal;\">\ud83d\udfe1 <\/span><span style=\"font-size: 16px;\">In the case of flexible aluminum conduit, the strip material must meet similar tensile strength requirements, with a minimum tensile strength of 34,000 lbf\/in\u00b2 (234.5 MPa).\u00a0<\/span><\/p>\n<p>\u2699\ufe0f Additionally, the copper content must be no more than 0.40%.<\/p>\n<p>The aluminum strip should maintain consistent width and thickness along its entire length for reliable performance.<\/p>\n<p>\u26a0\ufe0fWhen it comes to size, the thickness of the metal strip used in FMC must meet minimum values defined for standard wall conduits (see <strong>Table 5.1<\/strong>).<\/p>\n<p><img loading=\"lazy\" decoding=\"async\" class=\"alignnone wp-image-10477\" src=\"https:\/\/www.pvcconduitmanufacturer.com\/wp-content\/uploads\/2024\/10\/Choosing-the-Right-Flexible-Electrical-Conduit-for-Outdoor-Use-FMC-Sizes.png\" alt=\"Choosing the Right Flexible Electrical Conduit for Outdoor Use FMC Sizes\" width=\"800\" height=\"367\" title=\"\" srcset=\"https:\/\/www.pvcconduitmanufacturer.com\/wp-content\/uploads\/2024\/10\/Choosing-the-Right-Flexible-Electrical-Conduit-for-Outdoor-Use-FMC-Sizes.png 996w, https:\/\/www.pvcconduitmanufacturer.com\/wp-content\/uploads\/2024\/10\/Choosing-the-Right-Flexible-Electrical-Conduit-for-Outdoor-Use-FMC-Sizes-300x138.png 300w, https:\/\/www.pvcconduitmanufacturer.com\/wp-content\/uploads\/2024\/10\/Choosing-the-Right-Flexible-Electrical-Conduit-for-Outdoor-Use-FMC-Sizes-768x352.png 768w, https:\/\/www.pvcconduitmanufacturer.com\/wp-content\/uploads\/2024\/10\/Choosing-the-Right-Flexible-Electrical-Conduit-for-Outdoor-Use-FMC-Sizes-18x8.png 18w\" sizes=\"(max-width: 800px) 100vw, 800px\" \/><\/p>\n<p>However, reduced-wall FMC can have thinner metal strips if they meet specific reduced-wall standards.<\/p>\n<p><span style=\"font-size: 16px; font-style: normal; font-weight: 400;\">\ud83d\udccf<\/span>External diameter for flexible steel and aluminum conduits (sizes 3\/8\u201d to 4\u201d) must be within specified minimum and maximum limits (see <strong>Tables 9.1 &amp; 9.2<\/strong>). This ensures the conduit fits properly with connectors and other electrical parts.<\/p>\n<p><img loading=\"lazy\" decoding=\"async\" class=\"alignnone wp-image-10497\" src=\"https:\/\/www.pvcconduitmanufacturer.com\/wp-content\/uploads\/2024\/10\/Choosing-the-Right-Flexible-Electrical-Conduit-for-Outdoor-Use-FMC-Size.png\" alt=\"Choosing the Right Flexible Electrical Conduit for Outdoor Use FMC Size\" width=\"800\" height=\"668\" title=\"\" srcset=\"https:\/\/www.pvcconduitmanufacturer.com\/wp-content\/uploads\/2024\/10\/Choosing-the-Right-Flexible-Electrical-Conduit-for-Outdoor-Use-FMC-Size.png 799w, https:\/\/www.pvcconduitmanufacturer.com\/wp-content\/uploads\/2024\/10\/Choosing-the-Right-Flexible-Electrical-Conduit-for-Outdoor-Use-FMC-Size-300x250.png 300w, https:\/\/www.pvcconduitmanufacturer.com\/wp-content\/uploads\/2024\/10\/Choosing-the-Right-Flexible-Electrical-Conduit-for-Outdoor-Use-FMC-Size-768x641.png 768w, https:\/\/www.pvcconduitmanufacturer.com\/wp-content\/uploads\/2024\/10\/Choosing-the-Right-Flexible-Electrical-Conduit-for-Outdoor-Use-FMC-Size-14x12.png 14w\" sizes=\"(max-width: 800px) 100vw, 800px\" \/><\/p>\n<p>\ud83d\udee2\ufe0f Internal diameter also has minimum standards, and for conduits sized 3\/8\u201d to 2\u201d, it must not exceed a maximum size to provide enough room for wiring and avoid compression damage.<\/p>\n<h2><span class=\"ez-toc-section\" id=\"9_What_is_Electrical_Nonmetallic_Tubing\"><\/span>9. What is Electrical Nonmetallic Tubing?<span class=\"ez-toc-section-end\"><\/span><\/h2>\n<p><span style=\"font-size: 16px;\">Electrical Nonmetallic Tubing (ENT) is a nonmetallic, pliable, corrugated raceway of circular cross section. ENT is composed of a material that is resistant to moisture and chemical atmospheres and is flame retardant.<\/span><\/p>\n<p><strong>Features:<\/strong><\/p>\n<ul>\n<li>Made from PVC or polyethylene<\/li>\n<li>Flexible and waterproof<\/li>\n<\/ul>\n<p><strong>Key Benefits:<\/strong><\/p>\n<ul>\n<li>UV- and corrosion-resistant<\/li>\n<li>Easy to bend around corners<\/li>\n<li>Suitable for outdoor wet locations<\/li>\n<\/ul>\n<p><strong>Best for<\/strong>: <span style=\"font-size: 16px;\">Garden lighting systems, temporary outdoor setups, and coastal areas where corrosion resistance is key.<\/span><\/p>\n<p><img loading=\"lazy\" decoding=\"async\" class=\"alignnone wp-image-13141\" src=\"https:\/\/www.pvcconduitmanufacturer.com\/wp-content\/uploads\/2023\/08\/PVC-Flexible-Conduit-Packing.jpg\" alt=\"Kemasan Pipa Fleksibel PVC\" width=\"800\" height=\"457\" title=\"\" srcset=\"https:\/\/www.pvcconduitmanufacturer.com\/wp-content\/uploads\/2023\/08\/PVC-Flexible-Conduit-Packing.jpg 868w, https:\/\/www.pvcconduitmanufacturer.com\/wp-content\/uploads\/2023\/08\/PVC-Flexible-Conduit-Packing-300x171.jpg 300w, https:\/\/www.pvcconduitmanufacturer.com\/wp-content\/uploads\/2023\/08\/PVC-Flexible-Conduit-Packing-768x439.jpg 768w, https:\/\/www.pvcconduitmanufacturer.com\/wp-content\/uploads\/2023\/08\/PVC-Flexible-Conduit-Packing-18x10.jpg 18w\" sizes=\"(max-width: 800px) 100vw, 800px\" \/><\/p>\n<p>\ud83d\udccc According to the UL 1653 standard, <a href=\"https:\/\/www.pvcconduitmanufacturer.com\/id\/ul-listed-flexible-pvc-conduit-electrical-nonmetallic-tubing\/\"><strong><span style=\"color: #003473;\">THT<\/span><\/strong><\/a> must be made from rigid (non-plasticized) PVC to provide long-lasting strength and durability.<\/p>\n<p>\ud83d\udd17 Additionally, the fittings used with ENT should be made from materials that meet a minimum Relative Thermal Index (RTI) of 90\u00b0C (194\u00b0F)\u2014both for electrical properties and mechanical (non-impact) performance, in accordance with UL 746B and CAN\/CSA-C22.2 No. 0.17.<\/p>\n<p><span style=\"font-size: 16px;\">\ud83d\udca1 According to UL 1653,\u00a0 ENT is designed for use in specific temperature and installation conditions:<\/span><\/p>\n<p>\ud83d\udcc8 Continuous operating temperature: up to 75\u00b0C (167\u00b0F)<\/p>\n<p>\ud83c\udf21\ufe0f Maximum ambient temperature: up to 50\u00b0C (122\u00b0F)<\/p>\n<p>In attic installations, ENT must:<\/p>\n<ul>\n<li>Be installed no more than 900 mm (3 feet) above the ceiling joist bottom<\/li>\n<li>Be rated for at least 60\u00b0C (140\u00b0F) to perform safely in warmer spaces<\/li>\n<\/ul>\n<p>ENT is available in different trade sizes, all defined by standard dimensions listed in Table 1.<\/p>\n<p><img loading=\"lazy\" decoding=\"async\" class=\"alignnone wp-image-10476\" src=\"https:\/\/www.pvcconduitmanufacturer.com\/wp-content\/uploads\/2024\/10\/Choosing-the-Right-Flexible-Electrical-Conduit-for-Outdoor-Use-ENT-Sizes.png\" alt=\"Choosing the Right Flexible Electrical Conduit for Outdoor Use ENT Sizes\" width=\"800\" height=\"321\" title=\"\" srcset=\"https:\/\/www.pvcconduitmanufacturer.com\/wp-content\/uploads\/2024\/10\/Choosing-the-Right-Flexible-Electrical-Conduit-for-Outdoor-Use-ENT-Sizes.png 772w, https:\/\/www.pvcconduitmanufacturer.com\/wp-content\/uploads\/2024\/10\/Choosing-the-Right-Flexible-Electrical-Conduit-for-Outdoor-Use-ENT-Sizes-300x120.png 300w, https:\/\/www.pvcconduitmanufacturer.com\/wp-content\/uploads\/2024\/10\/Choosing-the-Right-Flexible-Electrical-Conduit-for-Outdoor-Use-ENT-Sizes-768x308.png 768w, https:\/\/www.pvcconduitmanufacturer.com\/wp-content\/uploads\/2024\/10\/Choosing-the-Right-Flexible-Electrical-Conduit-for-Outdoor-Use-ENT-Sizes-18x7.png 18w\" sizes=\"(max-width: 800px) 100vw, 800px\" \/><\/p>\n<p>Want to dive deeper into this conduit type?<\/p>\n<p>\ud83d\udc49 Check out our detailed guide:<\/p>\n<p><span style=\"color: #003473;\"><a style=\"color: #003473;\" href=\"https:\/\/www.ctube-gr.com\/news\/the-ultimate-guide-to-electrical-nonmetallic-tubing-ent-everything-you-need-to-know.html\" target=\"_blank\" rel=\"noopener\"><strong>The Ultimate Guide to Electrical Nonmetallic Tubing (ENT): Everything You Need to Know<\/strong><\/a><\/span><\/p>\n<div style=\"border: 1px solid #ddd; border-radius: 12px; padding: 16px; margin: 16px 0; background: #f9f9f9; box-shadow: 0 2px 8px rgba(0,0,0,0.05);\">\n<h3 style=\"margin-top: 0; font-size: 20px; color: #333;\">\ud83c\udfa5 Video about ENT for you if you are interested in.<\/h3>\n<div style=\"position: relative; width: 100%; padding-top: 56.25%; margin-bottom: 16px;\"><iframe style=\"position: absolute; top: 0; left: 0; width: 100%; height: 100%; border: none;\" src=\"https:\/\/www.youtube.com\/embed\/p1SHAwuiLy8?si=u1VDi6v1UhNgb2ZE\" allowfullscreen=\"allowfullscreen\"><\/iframe><\/div>\n<p><a style=\"display: inline-block; padding: 10px 20px; background-color: #003473; color: white; text-decoration: none; border-radius: 6px; font-weight: bold;\" href=\"https:\/\/www.youtube.com\/@ctubeofficialchannel\" target=\"_blank\" rel=\"noopener\">Follow Ctube to Learn More<\/a><span style=\"font-size: 16px; background-color: #ffffff;\">\u00a0<\/span><\/p>\n<\/div>\n<h2><span class=\"ez-toc-section\" id=\"10_What_is_High_Density_Polyethylene_Conduit\"><\/span><span style=\"font-size: 1.1em; font-weight: bold;\">10. What is High Density Polyethylene Conduit?<\/span><span class=\"ez-toc-section-end\"><\/span><\/h2>\n<p>High-Density Polyethylene (HDPE) conduit is a nonmetallic raceway with a circular shape, known for its flexibility and moisture resistance.<\/p>\n<p><strong>Features:<\/strong><\/p>\n<ul>\n<li>Constructed from polyethylene<\/li>\n<li>Designed for underground or outdoor use<\/li>\n<\/ul>\n<p><strong>Key Benefits:<\/strong><\/p>\n<ul>\n<li>Outstanding waterproofing and corrosion resistance<\/li>\n<li>High impact strength and flexibility<\/li>\n<li>Withstands extreme cold and heat<\/li>\n<\/ul>\n<p><strong>Best for<\/strong>: <span style=\"font-size: 16px;\">Long-term underground installations in harsh environments such as solar energy systems, utility wiring, and telecom cabling.<\/span><img loading=\"lazy\" decoding=\"async\" class=\"alignnone wp-image-10491\" style=\"font-style: inherit; font-weight: inherit;\" src=\"https:\/\/www.pvcconduitmanufacturer.com\/wp-content\/uploads\/2024\/10\/Choosing-the-Right-Flexible-Electrical-Conduit-for-Outdoor-Use-HDPE-Conduit.jpg\" alt=\"Choosing the Right Flexible Electrical Conduit for Outdoor Use HDPE Conduit\" width=\"800\" height=\"352\" title=\"\" srcset=\"https:\/\/www.pvcconduitmanufacturer.com\/wp-content\/uploads\/2024\/10\/Choosing-the-Right-Flexible-Electrical-Conduit-for-Outdoor-Use-HDPE-Conduit.jpg 750w, https:\/\/www.pvcconduitmanufacturer.com\/wp-content\/uploads\/2024\/10\/Choosing-the-Right-Flexible-Electrical-Conduit-for-Outdoor-Use-HDPE-Conduit-300x132.jpg 300w, https:\/\/www.pvcconduitmanufacturer.com\/wp-content\/uploads\/2024\/10\/Choosing-the-Right-Flexible-Electrical-Conduit-for-Outdoor-Use-HDPE-Conduit-18x8.jpg 18w\" sizes=\"(max-width: 800px) 100vw, 800px\" \/><\/p>\n<p>It comes in several common types such as Schedule 40, Schedule 80, EPEC-A, and EPEC-B, based on classifications defined under UL 651B, the standard for continuous-length HDPE conduit.<\/p>\n<p>\ud83d\udd0d <strong>Note<\/strong>: The &#8220;Schedule 40&#8221; and &#8220;Schedule 80&#8221; mentioned here refer to types of HDPE conduit and should not be confused with rigid PVC Schedule 40 or Schedule 80 conduit, which are defined under different standards (such as UL 651 for rigid PVC). While the naming is similar, the materials, physical characteristics, and installation methods are different.<\/p>\n<p>When choosing the right HDPE conduit, it\u2019s also important to consider the sizes and types available.<\/p>\n<p>These size limits are outlined in standardized tables like Table 5.1 for outer diameters, and Tables 5.2 and 5.3 for wall thicknesses.<\/p>\n<p><img loading=\"lazy\" decoding=\"async\" class=\"alignnone wp-image-10479\" src=\"https:\/\/www.pvcconduitmanufacturer.com\/wp-content\/uploads\/2024\/10\/Choosing-the-Right-Flexible-Electrical-Conduit-for-Outdoor-Use-HDPE-Conduit-Sizes.png\" alt=\"Choosing the Right Flexible Electrical Conduit for Outdoor Use HDPE Conduit Sizes\" width=\"800\" height=\"775\" title=\"\" srcset=\"https:\/\/www.pvcconduitmanufacturer.com\/wp-content\/uploads\/2024\/10\/Choosing-the-Right-Flexible-Electrical-Conduit-for-Outdoor-Use-HDPE-Conduit-Sizes.png 766w, https:\/\/www.pvcconduitmanufacturer.com\/wp-content\/uploads\/2024\/10\/Choosing-the-Right-Flexible-Electrical-Conduit-for-Outdoor-Use-HDPE-Conduit-Sizes-300x291.png 300w, https:\/\/www.pvcconduitmanufacturer.com\/wp-content\/uploads\/2024\/10\/Choosing-the-Right-Flexible-Electrical-Conduit-for-Outdoor-Use-HDPE-Conduit-Sizes-12x12.png 12w\" sizes=\"(max-width: 800px) 100vw, 800px\" \/><\/p>\n<p>Limits on the wall thicknesses<\/p>\n<p><img loading=\"lazy\" decoding=\"async\" class=\"alignnone wp-image-10478\" src=\"https:\/\/www.pvcconduitmanufacturer.com\/wp-content\/uploads\/2024\/10\/Choosing-the-Right-Flexible-Electrical-Conduit-for-Outdoor-Use-HDPE-Conduit-Size.png\" alt=\"Choosing the Right Flexible Electrical Conduit for Outdoor Use HDPE Conduit Size\" width=\"800\" height=\"423\" title=\"\" srcset=\"https:\/\/www.pvcconduitmanufacturer.com\/wp-content\/uploads\/2024\/10\/Choosing-the-Right-Flexible-Electrical-Conduit-for-Outdoor-Use-HDPE-Conduit-Size.png 771w, https:\/\/www.pvcconduitmanufacturer.com\/wp-content\/uploads\/2024\/10\/Choosing-the-Right-Flexible-Electrical-Conduit-for-Outdoor-Use-HDPE-Conduit-Size-300x159.png 300w, https:\/\/www.pvcconduitmanufacturer.com\/wp-content\/uploads\/2024\/10\/Choosing-the-Right-Flexible-Electrical-Conduit-for-Outdoor-Use-HDPE-Conduit-Size-768x406.png 768w, https:\/\/www.pvcconduitmanufacturer.com\/wp-content\/uploads\/2024\/10\/Choosing-the-Right-Flexible-Electrical-Conduit-for-Outdoor-Use-HDPE-Conduit-Size-18x10.png 18w\" sizes=\"(max-width: 800px) 100vw, 800px\" \/><\/p>\n<p>To meet performance requirements, HDPE conduit must also withstand tests of mechanical strength and temperature performance.<\/p>\n<h2><span class=\"ez-toc-section\" id=\"11_Key_Environmental_Requirements_for_Outdoor_Flexible_Conduit\"><\/span>11. Key Environmental Requirements for Outdoor Flexible Conduit<span class=\"ez-toc-section-end\"><\/span><\/h2>\n<p><span style=\"font-size: 16px;\">Outdoor environments can be harsh, so the conduit must be designed to withstand a range of challenging conditions.<\/span><\/p>\n<p><img loading=\"lazy\" decoding=\"async\" class=\"alignnone wp-image-10486\" src=\"https:\/\/www.pvcconduitmanufacturer.com\/wp-content\/uploads\/2024\/10\/Choosing-the-Right-Flexible-Electrical-Conduit-for-Outdoor-Use-Conduit-Installation.jpg\" alt=\"Choosing the Right Flexible Electrical Conduit for Outdoor Use Conduit Installation\" width=\"800\" height=\"533\" title=\"\" srcset=\"https:\/\/www.pvcconduitmanufacturer.com\/wp-content\/uploads\/2024\/10\/Choosing-the-Right-Flexible-Electrical-Conduit-for-Outdoor-Use-Conduit-Installation.jpg 1024w, https:\/\/www.pvcconduitmanufacturer.com\/wp-content\/uploads\/2024\/10\/Choosing-the-Right-Flexible-Electrical-Conduit-for-Outdoor-Use-Conduit-Installation-300x200.jpg 300w, https:\/\/www.pvcconduitmanufacturer.com\/wp-content\/uploads\/2024\/10\/Choosing-the-Right-Flexible-Electrical-Conduit-for-Outdoor-Use-Conduit-Installation-768x512.jpg 768w, https:\/\/www.pvcconduitmanufacturer.com\/wp-content\/uploads\/2024\/10\/Choosing-the-Right-Flexible-Electrical-Conduit-for-Outdoor-Use-Conduit-Installation-18x12.jpg 18w\" sizes=\"(max-width: 800px) 100vw, 800px\" \/><\/p>\n<ul>\n<li><strong>Waterproof and Moisture Resistance<\/strong>: The conduit must prevent water ingress to protect electrical wiring from damage and short-circuiting, especially in rainy or humid environments.<\/li>\n<li><strong>Ketahanan Korosi<\/strong>: Outdoor installations are often exposed to elements that can cause corrosion, particularly in coastal areas or industrial zones. The material must be resistant to corrosion to ensure long-lasting performance.<\/li>\n<li><strong>UV Resistance<\/strong>: Sun exposure can degrade materials over time. A UV-resistant conduit is essential to prevent brittleness or cracking due to prolonged exposure to sunlight.<\/li>\n<li><strong>Temperature Tolerance<\/strong>: Outdoor conduits must be able to withstand extreme temperature fluctuations, both high and low, to prevent material expansion, contraction, or degradation.<\/li>\n<li><strong>Pressure and Impact Resistance<\/strong>: In areas where the conduit may be subject to physical stress, such as being buried underground or mounted in exposed locations, it should be able to withstand pressure and potential impacts without damage.<\/li>\n<\/ul>\n<h2><span class=\"ez-toc-section\" id=\"12_Comparing_Different_Flexible_Conduit_Types\"><\/span>12. Comparing Different Flexible Conduit Types<span class=\"ez-toc-section-end\"><\/span><\/h2>\n<p>We compare different flexible conduits based on these essential test standards in the following to help you make the right choice for electrical conduit selecting.<\/p>\n<p><img loading=\"lazy\" decoding=\"async\" class=\"alignnone wp-image-10474\" src=\"https:\/\/www.pvcconduitmanufacturer.com\/wp-content\/uploads\/2024\/10\/Choosing-the-Right-Flexible-Electrical-Conduit-for-Outdoor-Use-Comparison.png\" alt=\"Choosing the Right Flexible Electrical Conduit for Outdoor Use Comparison\" width=\"800\" height=\"600\" title=\"\" srcset=\"https:\/\/www.pvcconduitmanufacturer.com\/wp-content\/uploads\/2024\/10\/Choosing-the-Right-Flexible-Electrical-Conduit-for-Outdoor-Use-Comparison.png 1024w, https:\/\/www.pvcconduitmanufacturer.com\/wp-content\/uploads\/2024\/10\/Choosing-the-Right-Flexible-Electrical-Conduit-for-Outdoor-Use-Comparison-300x225.png 300w, https:\/\/www.pvcconduitmanufacturer.com\/wp-content\/uploads\/2024\/10\/Choosing-the-Right-Flexible-Electrical-Conduit-for-Outdoor-Use-Comparison-768x576.png 768w, https:\/\/www.pvcconduitmanufacturer.com\/wp-content\/uploads\/2024\/10\/Choosing-the-Right-Flexible-Electrical-Conduit-for-Outdoor-Use-Comparison-16x12.png 16w\" sizes=\"(max-width: 800px) 100vw, 800px\" \/><\/p>\n<p>And we Uprovide a Use Case Comparison Table to help you better choose the conduit of your outdoor projects.<\/p>\n<div style=\"display: flex; flex-direction: column; gap: 16px; margin-bottom: 1em;\">\n<div style=\"border: 1px solid #ddd; border-radius: 8px; padding: 16px; background: #ffffff;\">\n<p><strong>Application:<\/strong> Garden or wet area<\/p>\n<p><strong>Recommended Type:<\/strong> LFMC \/ LFNC<\/p>\n<p><strong>Why:<\/strong> Waterproof, flexible<\/p>\n<\/div>\n<div style=\"border: 1px solid #ddd; border-radius: 8px; padding: 16px; background: #f1f3f5;\">\n<p><strong>Application:<\/strong> High stress \/ heavy load<\/p>\n<p><strong>Recommended Type:<\/strong> LFMC \/ FMC<\/p>\n<p><strong>Why:<\/strong> Strong mechanical protection<\/p>\n<\/div>\n<div style=\"border: 1px solid #ddd; border-radius: 8px; padding: 16px; background: #ffffff;\">\n<p><strong>Application:<\/strong> Humid \/ coastal area<\/p>\n<p><strong>Recommended Type:<\/strong> LFNC \/ Nonmetallic<\/p>\n<p><strong>Why:<\/strong> Corrosion and UV resistant<\/p>\n<\/div>\n<div style=\"border: 1px solid #ddd; border-radius: 8px; padding: 16px; background: #f1f3f5;\">\n<p><strong>Application:<\/strong> Underground \/ solar<\/p>\n<p><strong>Recommended Type:<\/strong> HDPE<\/p>\n<p><strong>Why:<\/strong> Extreme durability and flexibility<\/p>\n<\/div>\n<div style=\"border: 1px solid #ddd; border-radius: 8px; padding: 16px; background: #ffffff;\">\n<p><strong>Application:<\/strong> Outdoor lighting<\/p>\n<p><strong>Recommended Type:<\/strong> LFNC<\/p>\n<p><strong>Why:<\/strong> Easy to install, affordable<\/p>\n<\/div>\n<\/div>\n<p>&nbsp;<\/p>\n<h2><span class=\"ez-toc-section\" id=\"13_Flexible_Electrical_Conduit_Codes_Standards_And_Certifications\"><\/span>13. Flexible Electrical Conduit Codes, Standards And Certifications<span class=\"ez-toc-section-end\"><\/span><\/h2>\n<p>To enhance your understanding, we provide some references to the relevant flexible catheter standards. Different standards may cater to various end uses and applications, so it\u2019s important to review the scope of each standard to grasp its intended purpose.<\/p>\n<p><img loading=\"lazy\" decoding=\"async\" class=\"alignnone wp-image-10475\" src=\"https:\/\/www.pvcconduitmanufacturer.com\/wp-content\/uploads\/2024\/10\/Choosing-the-Right-Flexible-Electrical-Conduit-for-Outdoor-Use-Conduit-Standards.png\" alt=\"Choosing the Right Flexible Electrical Conduit for Outdoor Use Conduit Standards\" width=\"800\" height=\"457\" title=\"\" srcset=\"https:\/\/www.pvcconduitmanufacturer.com\/wp-content\/uploads\/2024\/10\/Choosing-the-Right-Flexible-Electrical-Conduit-for-Outdoor-Use-Conduit-Standards.png 1267w, https:\/\/www.pvcconduitmanufacturer.com\/wp-content\/uploads\/2024\/10\/Choosing-the-Right-Flexible-Electrical-Conduit-for-Outdoor-Use-Conduit-Standards-300x171.png 300w, https:\/\/www.pvcconduitmanufacturer.com\/wp-content\/uploads\/2024\/10\/Choosing-the-Right-Flexible-Electrical-Conduit-for-Outdoor-Use-Conduit-Standards-1024x585.png 1024w, https:\/\/www.pvcconduitmanufacturer.com\/wp-content\/uploads\/2024\/10\/Choosing-the-Right-Flexible-Electrical-Conduit-for-Outdoor-Use-Conduit-Standards-768x439.png 768w, https:\/\/www.pvcconduitmanufacturer.com\/wp-content\/uploads\/2024\/10\/Choosing-the-Right-Flexible-Electrical-Conduit-for-Outdoor-Use-Conduit-Standards-18x10.png 18w\" sizes=\"(max-width: 800px) 100vw, 800px\" \/><\/p>\n<h3>14. Conclusion<\/h3>\n<p>This post provides a detailed overview of the different types of flexible electrical conduits, highlighting the unique benefits and features of each material.<\/p>\n<p>In summary, selecting and choosing the right flexible conduit for outdoor use means carefully assessing your project\u2019s environment, application needs, budget, and regulatory requirements to achieve the best performance and safety.<\/p>\n<p><img loading=\"lazy\" decoding=\"async\" class=\"alignnone wp-image-10487\" src=\"https:\/\/www.pvcconduitmanufacturer.com\/wp-content\/uploads\/2024\/10\/Choosing-the-Right-Flexible-Electrical-Conduit-for-Outdoor-Use-Ctube-ENT.jpg\" alt=\"Choosing the Right Flexible Electrical Conduit for Outdoor Use Ctube ENT\" width=\"800\" height=\"482\" title=\"\" srcset=\"https:\/\/www.pvcconduitmanufacturer.com\/wp-content\/uploads\/2024\/10\/Choosing-the-Right-Flexible-Electrical-Conduit-for-Outdoor-Use-Ctube-ENT.jpg 1000w, https:\/\/www.pvcconduitmanufacturer.com\/wp-content\/uploads\/2024\/10\/Choosing-the-Right-Flexible-Electrical-Conduit-for-Outdoor-Use-Ctube-ENT-300x181.jpg 300w, https:\/\/www.pvcconduitmanufacturer.com\/wp-content\/uploads\/2024\/10\/Choosing-the-Right-Flexible-Electrical-Conduit-for-Outdoor-Use-Ctube-ENT-768x463.jpg 768w, https:\/\/www.pvcconduitmanufacturer.com\/wp-content\/uploads\/2024\/10\/Choosing-the-Right-Flexible-Electrical-Conduit-for-Outdoor-Use-Ctube-ENT-18x12.jpg 18w\" sizes=\"(max-width: 800px) 100vw, 800px\" \/><\/p>\n<p>Ctube is a professional conduit manufacturer, dedicated to providing reliable and durable products for versatile electrical installations.<\/p>\n<p>Kita <span style=\"color: #003473;\"><strong><a style=\"color: #003473;\" href=\"https:\/\/www.pvcconduitmanufacturer.com\/id\/pipa-saluran-listrik-fleksibel\/\">PVC flexible conduits<\/a><\/strong><\/span> comply with international certifications such as UL 651, AS\/NZS 2053, and CSA, ensuring exceptional flexibility, durability, and safety across different environments.<\/p>\n<p>Ctube also provides special flexible conduit series :<strong> the <span style=\"color: #003473;\"><a style=\"color: #003473;\" href=\"https:\/\/www.pvcconduitmanufacturer.com\/id\/solar-pvc-conduit-pipe-series\/\">Solar Conduit <\/a>Series<\/span><\/strong> and the <span style=\"color: #003473;\"><strong><a style=\"color: #003473;\" href=\"https:\/\/www.pvcconduitmanufacturer.com\/id\/lszh-electrical-conduit-pipe-series\/\">Low Smoke Halogen-Free (LSZH) Conduit<\/a> Series<\/strong><\/span>.<\/p>\n<p>If you are searching for outdoor conduit for your projects and interested in our products, feel free to contact us for more information.<\/p>\n<p>Thank you for reading. Hope your project goes well.<\/p>\n<p><img loading=\"lazy\" decoding=\"async\" class=\"alignnone wp-image-13189 size-full\" src=\"https:\/\/www.pvcconduitmanufacturer.com\/wp-content\/uploads\/2024\/10\/FAQS.jpg\" alt=\"FAQS\" width=\"800\" height=\"246\" title=\"\" srcset=\"https:\/\/www.pvcconduitmanufacturer.com\/wp-content\/uploads\/2024\/10\/FAQS.jpg 800w, https:\/\/www.pvcconduitmanufacturer.com\/wp-content\/uploads\/2024\/10\/FAQS-300x92.jpg 300w, https:\/\/www.pvcconduitmanufacturer.com\/wp-content\/uploads\/2024\/10\/FAQS-768x236.jpg 768w, https:\/\/www.pvcconduitmanufacturer.com\/wp-content\/uploads\/2024\/10\/FAQS-18x6.jpg 18w\" sizes=\"(max-width: 800px) 100vw, 800px\" \/><\/p>\n<h2><span class=\"ez-toc-section\" id=\"FAQs\"><\/span>Pertanyaan yang Sering Diajukan (FAQ)<span class=\"ez-toc-section-end\"><\/span><\/h2>\n<div id=\"rank-math-rich-snippet-wrapper\"><div id=\"rank-math-faq\" class=\"rank-math-block\">\n<div class=\"rank-math-list\">\n<div id=\"faq-1\" class=\"rank-math-list-item\">\n<h3 class=\"rank-math-question\">How do I know which flexible conduit material is best for my project?<\/h3>\n<div class=\"rank-math-answer\">\n\n<p>To choose the right conduit, consider factors such as the environmental conditions (e.g., moisture, UV exposure), mechanical protection needs, safety requirements, project budget, and local regulations. For example, PVC conduits are cost-effective and corrosion-resistant, while metal conduits offer higher durability and impact protection.<\/p>\n\n<\/div>\n<\/div>\n<div id=\"faq-2\" class=\"rank-math-list-item\">\n<h3 class=\"rank-math-question\">How long do flexible conduits last in outdoor installations?<\/h3>\n<div class=\"rank-math-answer\">\n\n<p>The longevity of flexible conduits in outdoor installations depends on the material and environmental conditions. PVC conduits are highly resistant to corrosion and UV damage, while metal conduits provide long-lasting durability against physical stress. Regular maintenance and inspection can further extend the lifespan of the conduits.<\/p>\n\n<\/div>\n<\/div>\n<div id=\"faq-3\" class=\"rank-math-list-item\">\n<h3 class=\"rank-math-question\">How do flexible conduits compare to rigid conduits for outdoor use?<\/h3>\n<div class=\"rank-math-answer\">\n\n<p>Flexible conduits are easier to install in complex layouts and areas with tight spaces or movement. They are ideal for applications where adaptability is required. However, rigid conduits offer higher mechanical protection and are generally used in areas where the conduit does not need to bend or twist. Both types have their advantages depending on the application and environment.<\/p>\n\n<\/div>\n<\/div>\n<\/div>\n<\/div><\/div>","protected":false},"excerpt":{"rendered":"<p>1. Introduction Can flexible conduit be used outdoors? The answer is yes! \ud83c\udf1eBut to make sure your outdoor wiring stays safe and lasts long, you need to choose the right type of flexible electrical conduit that suits the outdoor environment. \ud83d\udd0dFor example, a contractor once installed a flexible conduit for a garden lighting system without [&hellip;]<\/p>\n","protected":false},"author":1,"featured_media":13067,"comment_status":"open","ping_status":"open","sticky":false,"template":"","format":"standard","meta":{"_lmt_disableupdate":"no","_lmt_disable":"","_sitemap_exclude":false,"_sitemap_priority":"","_sitemap_frequency":"","site-sidebar-layout":"default","site-content-layout":"","ast-site-content-layout":"default","site-content-style":"default","site-sidebar-style":"default","ast-global-header-display":"","ast-banner-title-visibility":"","ast-main-header-display":"","ast-hfb-above-header-display":"","ast-hfb-below-header-display":"","ast-hfb-mobile-header-display":"","site-post-title":"","ast-breadcrumbs-content":"","ast-featured-img":"","footer-sml-layout":"","ast-disable-related-posts":"","theme-transparent-header-meta":"default","adv-header-id-meta":"","stick-header-meta":"","header-above-stick-meta":"","header-main-stick-meta":"","header-below-stick-meta":"","astra-migrate-meta-layouts":"set","ast-page-background-enabled":"default","ast-page-background-meta":{"desktop":{"background-color":"var(--ast-global-color-4)","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""},"tablet":{"background-color":"","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""},"mobile":{"background-color":"","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""}},"ast-content-background-meta":{"desktop":{"background-color":"var(--ast-global-color-5)","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""},"tablet":{"background-color":"var(--ast-global-color-5)","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""},"mobile":{"background-color":"var(--ast-global-color-5)","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""}},"_joinchat":[],"footnotes":""},"categories":[82,13,46,56,204],"tags":[229,522,521,251,524,523],"class_list":["post-10473","post","type-post","status-publish","format-standard","has-post-thumbnail","hentry","category-conduit-fittings","category-electrical-conduit-pipe","category-electrical-metallic-tubing","category-electrical-nonmetallic-tubing","category-industry-news","tag-electrical-metallic-tubing","tag-electrical-nonmetallic-tubing","tag-flexible-conduit","tag-hdpe-conduit","tag-metal-flexible-conduit","tag-pvc-flexible-conduit"],"modified_by":"ctubeofficialchina","_links":{"self":[{"href":"https:\/\/www.pvcconduitmanufacturer.com\/id\/wp-json\/wp\/v2\/posts\/10473","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/www.pvcconduitmanufacturer.com\/id\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/www.pvcconduitmanufacturer.com\/id\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/www.pvcconduitmanufacturer.com\/id\/wp-json\/wp\/v2\/users\/1"}],"replies":[{"embeddable":true,"href":"https:\/\/www.pvcconduitmanufacturer.com\/id\/wp-json\/wp\/v2\/comments?post=10473"}],"version-history":[{"count":0,"href":"https:\/\/www.pvcconduitmanufacturer.com\/id\/wp-json\/wp\/v2\/posts\/10473\/revisions"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/www.pvcconduitmanufacturer.com\/id\/wp-json\/wp\/v2\/media\/13067"}],"wp:attachment":[{"href":"https:\/\/www.pvcconduitmanufacturer.com\/id\/wp-json\/wp\/v2\/media?parent=10473"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/www.pvcconduitmanufacturer.com\/id\/wp-json\/wp\/v2\/categories?post=10473"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/www.pvcconduitmanufacturer.com\/id\/wp-json\/wp\/v2\/tags?post=10473"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}